DescriptionHP368 50Hz~3.8GHz Digital RF Power Meter -60 To +7dBm RF Power Detector For Power Measurement
1. Overview:
HP368 is a radio frequency power meter. The meter is operated by pressing the keys. Its advantages: simple structure, convenient use, stable performance, reliability, high sensitivity and fast measurement speed.
2. Application:
â RF power measurement;
â Meter calibration.
3. Technical Parameters:
1. Measuring power range: -60 to +7dBm (External RF attenuator can be extended to 100dBm)
2. Measurement power resolution: 0.1 dBm
3. Measuring frequency range: 50Hzï½3800 MHz (50Hz~3.8GHz)
4. Measuring power: 1nWï½1W
5. Working voltage: 7ï½12 VDC
6. Working current: <50 mA
7. Working temperature: -40â to 65â
8. Storage temperature: -40âto 65â
9. Size: 55*45*10 mm (LxWxH)
4. Interface Display & Operation Instructions:
(1) Unit description: dBm;
(2) Key description:
FUN: Function key; MODE: Change interface; SEL: Self-up key or self-decrement key.
4.1. Display Measurement Data
Interface display font:
The first line "RF-POW -65.5 dBm"
The second line "110uV 0nW"
Note: Display the signal dBm value, input voltage value, and input power respectively.
4.2. Set RF Power Attenuation Value
Interface display font:
The first line "RF Attenuator"
The second line "SUB 00.0dB"
Key operation:
FUN: Function key; (select the direction of addition and subtraction) Display SUB for subtraction, display ADD for addition. (Long press the FUN key to save the set dB value)
SEL: Self-increasing key or self-decreasing key.
4.3. Set the Value of Measurement Frequency (function: modify the radio frequency power of different frequencies)
Interface display font:
The first line "Measuring freq"
The second line "SUB 00.0GHz"
Key operation:
FUN: Function key; (select the direction of addition and subtraction) SUB is displayed for subtraction, and ADD is displayed for addition. (Long press the FUN key to save the set frequency value)
SEL: Self-increasing key or self-decreasing key.
Note: Connect different RF power attenuators and set the corresponding attenuation coefficient to read out the correct power parameters.
5. Wiring:
P1. Wiring Definition:
No. Symbol Meaning
1. VDD: Module's positive power supply (7V~12V)
2. GND: The negative pole of the power supply of the module
P2 Wiring Definition:
No. Symbol Meaning
1. RF: Radio frequency signal input
2. GND: Power negative
Annotation:
First of all, dB is a pure counting unit: for power, dB = 10*lg(A/B). For voltage or current, dB = 20*lg(A/B). The meaning of dB could not be simpler, that is, a very large (followed by a long string of 0s) or a very small (preceded by a long string of 0s) number is expressed relatively shortly. Such as:
X=1000000000000000 (15 zeros in total)
It can be expressed as: 10lgX=150dB
X=0.000000000000001
It can be expressed as: 10lgX=-150 dB
dBm defines miliwatt (milliwatt). 0 dBm=1mw;
dBw defines watt. 0 dBW = 10lg1 W = 10lg1000 mw = 30 dBm.
By default, dB always defines the power unit, which is calculated as 10lg. Of course, in some cases, signal strength (Amplitude) can be used to describe work and power. In this case, use 20lg as the meter. This applies to both the control field and the signal processing field. For example, sometimes you can see the expression of dBmV.
Package Included:
- 1 x RF Power Meter
Payment Terms
1.We accept PayPal only.
2.All major credit cards are accepted through secure payment processor PayPal.
3.Payment must be received within 7 business days of auction closing.
4.We ship to your eBay or Paypal address. Please make sure your eBay and Paypal address is correct before you pay.
Shipping Terms
- For remote regions, we will charge your extra shipping costs. Usually it cost about 35USD-50USD. We will contact you after your payment. Thanks for your understanding.
Return Terms
1. If you receive defective item, please kindly notify us within 14 days. We will guide you the returning instruction for replacement or refund.
2. If you purchased in improper condition, please NOTE that the sipping and handling fee will not be refund, all return shipping fee should paid by the buyer unless item DOA.
3. We reserve the right to refuse any returns for objective reasons.
Custom Duties & Taxes
1. Import duties, taxes, and charges are not included in the item price or postage cost. These charges are the buyer's responsibility.
2. Avoiding some unnecessary trouble, please check with your country's customs office to inform us what we should declare its value before shipping.
Feedback
1. If you are dissatisfied for any reason, please don't be quick to leave us neutral or negative feedback. We work hard to make sure EVERY CUSTOMER 100% SATISFIED and resolve any problem for you and always leave positive feedback to all our customers.
2. If you are satisfied with the product you received, please kindly leave us a positive feedback and 5 star DSR. If there is any problem of your order, please feel free to contact us firstly, we are responsible and credible seller, will follow it for you asap.
On Nov-03-20 at 19:00:19 PST, seller added the following information: